EmmaT Eulerian Profiler
EMMA-T is a high accuracy temperature profiler, developed in partnership with Ifremer.
Eulerian profiler (fixed point profiler), it allows :
- Pressure and temperature measurement in the water column.
- Measures down to a depth of 6000m.
- Monitoring of specific areas over 2 years (strong currents, straits).
- Data retrieval via satellite.
EMMA-T advantages :
- The use of several EMMA-T systems at a single point allows time sampling of the water column.
- The use of several EMMA-T systems as a network allows space & time sampling of the water masses.
- It only requires one deployment campaign every 2 years.
- It is easily deployed from a ship of opportunity.
- Its surfacing at a preset time is automatic.
- The data transmission when the profiler reaches the surface allows an operational follow up of the water masses.
Main characteristics :
- Temperature measurement : Range -2°C +35°C Resolution 0.5m°C at 6°C Accuracy 3m°C from 0 to 10°C.
- Pressure measurement : Range 624 bars Resolution 0.15 bar.
- Programming from a PC-based software via radio link.
- Compressed data transmission via Argos.
- Energy autonomy for 6 days of transfer after 2 years stationed within the water column.
- Overall dimensions 60cm * 20cm.
- Weight in air 2.3kg.